Air flow control part supplies air flow for ventilator nebulization function, the flow ranges from 6 ~ 10 l/min
Technical Specification
Pneumatic Ventilator
R30
l Display
l Respiratory mode
l Graphical display
l Battery
l Data communication port
l 10.4”, TFT display, with touch screen
l VCV, PCV, SIMV-VC, SIMV-P, CPAP/PSV, BACKUP (Optional:Duophasic / APRV, NIV )
l P-T, F-T, V-T(Optional: CO2-time, pulserate-time)
l loop: P-V, F-V
l NI-MH battery, >120mins
l RS232, VGA, USB, Remote alarm
Operating Conditions
l Gas supply: Air, O2, 280kPa -600kPa (40~87 PSI)
l Power supply: 100-240V, 50/60Hz
l Temperature: 10-40℃ (Operation), -20-60℃ (Storage)
l Relative humidity: 5-95%, non-condensing (Operation)
≤95%, non-condensing (Storage)
l Atmospheric pressure (Operation & Storage): 500hPa-1060hPa
l Dimensions (H×W×D):
Ventilator: 455mm x 400mm x 300mm
Trolley: 565mm X 535mmX 910mm
l Weight:
Ventilator: 12.5 kg
Trolley: 20 kg
Pneumatic Ventilator
R30
l Display
l Respiratory mode
l Graphical display
l Battery
l Data communication port
l 10.4”, TFT display, with touch screen
l VCV, PCV, SIMV-VC, SIMV-P, CPAP/PSV, BACKUP (Optional:Duophasic / APRV, NIV )
l P-T, F-T, V-T(Optional: CO2-time, pulserate-time)
l loop: P-V, F-V
l NI-MH battery, >120mins
l RS232, VGA, USB, Remote alarm
Operating Conditions
l Gas supply: Air, O2, 280kPa -600kPa (40~87 PSI)
l Power supply: 100-240V, 50/60Hz
l Temperature: 10-40℃ (Operation), -20-60℃ (Storage)
l Relative humidity: 5-95%, non-condensing (Operation)
≤95%, non-condensing (Storage)
l Atmospheric pressure (Operation & Storage): 500hPa-1060hPa
l Dimensions (H×W×D):
Ventilator: 455mm x 400mm x 300mm
Trolley: 565mm X 535mmX 910mm
l Weight:
Ventilator: 12.5 kg
Trolley: 20 kg
20~3000 mL
1~99 L
22~100%, OFF
1~99 cmH2O
1~120 bpm
50~99%, OFF
0.1~13.3 kPa
31~250 bpm
OFF,20~2999 mL
0~98 L
20~100%
0~98 cmH2O
0~99 bpm
49~99%
0~13.2 kPa
30~249 bpm
Circuit occlusion
Apnea alarm
O2 SUPPLY DOWN alarm
Mains failure alarm
Battery power low alarm
Battery discharged alarm
Alarm silence
(PEEP+15) cmH2O, 15s
15~60s
< 280 kPa
Automatically switch
< 10 min
< 5 min
≤120 s
Auxiliary O2
Auxiliary O2 Flow meter(O2: 0~15LPM) (Optional)
ACGO
Yes
O2 Flush
25-75L/Min
Battery
NI-MH battery build in.
>90mins
Yoke
2 (O2, N2O) (Optional)
Gas Cylinder
O2, N2O (Optional)
Cycle Absorber
Intergrade, bypass Design, heating system.
Setting
Parameter
Monitoring
Parameter
Tidal volume (optional 20ml)
Respiratory frequency
Inspiratory time
Breath-hold time
Pressure triggering
Flowrate triggering
PEEP
Pressure support
Pressure control
High pressure level
Low pressure level
Oxygen concentration
100% O2
Thigh (optional)
freeze