Name: Medical Portable Touchscreen Siriusmed Ventilator
Keyword: Siriusmed Ventilator
Power Source: Electric
Material: Metal, Plastic
Warranty:: 1 Year
Instrument Classification: Class III
Widely Usage Range: Suitable For Infants And Adults
Tidal Volume Setting: 20~2500mL
Sufficient Modes Of Ventilation:: VCV, PCV, SIMV-VC, SIMV-PC, SPONT/CPAP+PSV, DuoPhasic
Friendly User Interface:: TFT Color Screen With Touch Screen
High Light:

R50 Intensive Care Ventilator

,

Intensive Care Ventilator 12"

,

Tft Display ventilator in icu

Basic Infomation
Brand Name: R50
Payment & Shipping Terms
Payment Terms: T/T
Product Description

ICU VENTILATOR R50- 12",TFT DISPLAY, WITH TOUCH SCREEN 

  • Sufficient modes of Ventilation: VCV, PCV, SIMV-VC+PSV, SIMV-PC+PSV, SPONT/CPAP+PSV, BACKUP, Manual
  • Optional:PRVC,SIMV-PRVC, NIV-PC,NIV-CPAP, DuoPhasic+PSV ,APRV+PSV

System Specifications

 

 

Pneumatic Ventilator
  • 12",TFT display, with touch screen
  • VCV, PCV, SIMV-VC, SIMV-PC, CPAP/PSV, BACKUP:见上描述
  • P-T, F-T, V-T, CO2-time, pulse rate-time,
  • loop: P-V, F-V
  • NI-MH battery, ≥90mins
  • RS232, VGA, USB, Remote alarm
Operating Conditions
  • Gas supply: Air, O2, 280kPa -600kPa (41~87 PSI)
  • Power supply: 100-240V, 50/60Hz
  • Temperature: 10-40℃ (Operation), -20-60℃ (Storage)
  • Relative humidity: 5-95%, non-condensing (Operation)

5-95% (Storage)

  • Atmospheric pressure (Operation & Storage): 500hPa-1060hPa
  • Dimensions (H×W×D):

Ventilator: 455mm x 400mm x 300mm

Trolley: 565mm X 535mmX 910mm

  • Weight:

Ventilator: 12.5 kg

Trolley: 20 kg

Standards
IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, ISO 80601-2-12
Alarm Upper limit Lower limit

Tidal volume

Minute volume

Oxygen concentration

Airway pressure

Respiratory frequency

ETCO2

Pulse rate

Circuit occlusion

Apnea alarm

O2 SUPPLY DOWN alarm

Mains failure alarm

Battery power low alarm

Battery discharged alarm

Alarm silence

20~3000 mL

1~99 L

22~100%, OFF

1~99 cmH2O

1~120 bpm

0.1~13.3 kPa

31~250 bpm

(PEEP+15) cmH2O, 15s

10~60s

< 280 kPa

Automatically switch

< 10 min

< 5 min

≤120 s

OFF,20~2999 mL

0~98 L

20~100%

0~98 cmH2O

OFF,1~99 bpm

0~13.2 kPa

30~249 bpm

(PEEP+15) cmH2O, 15s

10~60s

< 280 kPa

Automatically switch

< 10 min

< 5 min

≤120 s

Setting Parameter Monitoring Parameter

Tidal volume

Respiratory frequency

Inspiratory time

Breath-hold time

Pressure triggering

Flowrate triggering

PEEP

Pressure support

Pressure control

High pressure level

Low pressure level

Oxygen concentration

100% O2

Thigh

Tlow

freeze

Expiratory hold (optional)

Inspiratory hold (optional)

Manual inspiration (optional)

20~2500mL

1~120 bpm

0.1~12 s

0~50%

-20cmH2O~PEEP 0[1]

0.5~20 L/min

0~50 cmH2O

0~80 cmH2O

5~80 cmH2O

5~80 cmH2O

0~50 cmH2O

21~100%

2min

0.1~30s

0.2~30s

Yes

Yes

Yes

Yes

Inspiratory tidal volume

Expiratory tidal volume

Minute volume

Spontaneous minute volume

Spontaneous respiration frequency

 

PEEP

Airway peak pressure

Mean airway pressure

Inspiratory platform pressure

Minimum airway pressure

Inhaled oxygen concentration

Airway resistance

 

Compliance

RSBI

PEEPi

EtCO2 (Optional)

0~4000 mL

0~4000 mL

0~99 L

0~99 L/min

0~120 bpm

0~120 bpm

0~100 cmH2O

0~100 cmH2O

0~100 cmH2O

0~100 cmH2O

-20~100 cmH2O

15% ~100 %

0~600 cmH2O/(L/S)

0~300 mL/cmH2O

0 ~ 9999 bpm/L

0~100cmH2O

0 ~ 100 mmHg


Friendly interface

10.4”TFT touch screen, with a rotary knob.

  • High-resolution display suit for long-term application in ICU

Keyboard lock

  • Prevents accidental touching that could lead to parameter changes and endangering patient safety,
  • Key lock can be initiated any time during the operation interface.

Active Exhalation Valve

  • Achieves breathing during both inspiratory and expiratory.
  • Actively controls the target pressure, prevent airway pressure high
  • Promotes patient ventilator synchrony.
  • Modular exhalation valve & flow sensor is easily removable and serializable.

 

 

Recommended Products
Get in touch with us
Tel : +86 152 01065587
Fax : 86-10-87576461-801
Characters Remaining(20/3000)