Anesthetic Workstation X40, 8.4” LCD Human-computer interaction system with touch screen
anesthetic workstation X40
CO2 Absorber System
134°autoclavable CO2 absorber integrated bypass system, totally latex free.
Variable orifice flow sensor design.
35° (+-2) integrated heating system.
Bypass design with canister removes alarm.
No tools installation, easy maintenance.
System Specifications
System Specifications | |
Technical parameters | Specification |
Machine | |
Size | 1410 × 950 × 650 (H × W × D) |
Weight | 110kg |
Top cover | 30kg bearing weight |
Size | 580 x 400mm |
Display | |
Type | Color TFT (touch screen) |
Size | 8.4’ inches |
Resolution | 640 × 480 pixels |
Work surface light | LED |
LED indication | |
Alarm Indication | |
AC power | |
Battery | |
Audio instruction | |
Speaker | Alarm sounds |
Control | |
Button Press key | |
Interface | |
RS232, VGA, USB Three auxiliary output power interface |
|
Moving means | |
Castor |
4 antistatic castors, diameter Φ125mm (2 brake Infront) |
Toolbox | |
Drawer | 200 × 392 × 398 mm(H×W×D)x2 |
Respiratory System | |
Air bellow | 1500mL |
Absorption chamber | 1500mL |
Connection |
Suction / ACGO ports: standard OD 22mm, ID 15mm, tapered connector; Exhalation ports: standard OD 22mm, ID 15mm, tapered connector. Manual breathing port: diameterΦ22cm |
System leaks | < 40ml/min |
System compliance | ≤ 4 mL / cmH2O |
Resistance |
Inspiratory < 0.6 kPa; Expiratory < 0.6 kPa |
Vaporizer | |
Description | Parameter |
Technical Specification | |
Flowrate range | 0.2-15L/min |
Connector type | Selectatec compatible, plug in, cage mount |
Dosing methods | Pour-fil, Easy-fil, Quick-fil (Sevoflurane) |
Working environment | |
Working temperature | +15℃ ~ +35℃ |
Relative humidity | 5%~95%(non-condensing) |
Atmospheric pressure | 70kPa ~ 106kPa |
Storage temperature | -20℃ ~ +55℃ |
Concentration: |
0~5.0%: Isoflurane, Halothane 0 ~ 8.0%: Sevoflurane |
Main technical parameters | |
Description | Parameter |
Display | 8” TFT, Touch screen, Top light |
Ventilation Model | VCV, PCV, Manual, Standby SIMV-V (Optional:SIMV-P, SPONT/PSV) |
Tidal volume | 20-1500ml(optional 10-1600ml), Electronic PEEP, Lung mechanics parameters. |
Wave form | Paw-T, Flow-T, V-T, CO2-T |
Loop | P-V, V-F |
Pressure Monitoring
|
Central: O2, N2O, Air Cylinder: O2, N2O |
Monitoring Parameter
|
Tidal volume, MV, Frequency, I : E, Airway Pressure, Pmin, Compliance, Resistance |
Application | Adult and Infant |
Vaporizer | Selected bar for two position |
Gas supply | O2, N2O, Air |
6 tubes Flowmeter
|
O2: 0~10LPM; N2O: 0~12LPM; Air: 0~15LPM; |
O2% | O2 sensor |
Auxiliary O2 | Auxiliary O2 Flow meter(O2: 0~15LPM) (Optional) |
ACGO | Yes |
Battery |
NI-MH battery build-in. >90mins |
Yoke | 2 ( O2, N2O) (Optional) |
Gas Cylinder | O2, N2O (Optional) |
Cycle Absorber | Intergrade, bypass Design, heating system. |
Setting Parameter | |
Description | Parameter |
Tidal volume | 20~1500 mL(optional 10-1600ml) |
Frequency | 1~100 bpm |
Tinsp | 0.1~10.0s |
I:E | 4:1~1:10 |
Pause | 0~60% |
PEEP | OFF, 3~30 cmH2O |
Psupp | 0~70 cmH2O |
Pressure Control | 5~70 cmH2O |
Flow Trigger | 0.5~20 L/min |
Pressure Trigger | 0~20 cmH2O |
Ramp | 0~2s |
Monitoring Parameter | |
Description | Parameter |
Tidal volume Inspiration | 0~2500 mL |
Tidal volume Expiration | 0~2500 mL |
MV | 0~60 L/min |
MVspont | 0~60 L/min |
Frequency | 0~100 bpm |
Ratespont | 0~100 bpm |
I : E | 9:1~1:99 |
Ppeak | 0~100 cmH2O |
Pmean | 0~100 cmH2O |
PEEP | 0~100 cmH2O |
Pplat | 0~100 cmH2O |
O2% | 15~100% |
Compliance | 0~300 mL/cmH2O |
Resistance | 0~600 cmH2O/(L/s) |
EtCO2 (Optional) | 0~13.3 % |
FiCO2 (Optional) | 0~13.3 % |
Alarm Parameter | |
Description | Parameter |
Tidal volume | |
Upper limit | 30~2000 mL |
Lower limit | OFF, 20~1500 mL |
MV | |
Upper limit | 1~99 L |
Lower limit | 0~98 L |
O2% (Optional) | |
Upper limit | 22~100%, OFF |
Lower limit | 20~99% |
Airway Pressure | |
Upper limit | 10~99 cmH2O |
Lower limit | 1~98 cmH2O |
Frequency | |
Upper limit | 1~100 bpm |
Lower limit | 0~99 bpm |
EtCO2 (Optional) | |
Upper limit | 0.1~13.3 % ; |
Lower limit | 0~13.2 %; |
FiCO2 (Optional) | |
Upper limit | 0.1~13.3 % ; |
Continue Pressure High | Airway pressure beyond(PEEP+15)cm H2O, continuedly(15+1)s |
Apnea | 10~60 s, Increase: 1s |
O2 supply down | < 0.28 MPa |
Mains failure | Automatic switch battery |
Battery low | < 10 min |
Battery discharged | < 5 min |
Mute | ≤120 s |
Pressure low | < -10cmH2O |
Power Specifications | |
Description | Parameter |
External AC power | |
Input Voltage | 100 - 240V |
Input Frequency | 50/60Hz |
Input Power | <150 VA |
Internal Battery | |
Number of batteries | A battery pack |
Battery Type | Nimh batteries |
Rated battery voltage | 12VDC |
Battery capacity | 4200mAh |
Shutdown Delay | Less than 10min (using a new fully charged battery, low battery alert since the first post) |
Shortest supply time | 90min |
Charging time | 4h |
Work environment | |
Temperature | 10 ~ 40 ºC |
Humidity | 5 ~ 95%, non-condensing |
Environmental pressures | 70 ~ 106 kPa |
Storage environment | |
Temperature | -20 ~ 55 ºC |
Humidity | 5~ 95%, non-condensing |
Environmental pressures | 50 ~ 106 kPa |