Anesthetic Workstation X40, 8.4” LCD Human-computer interaction system with touch screen
anesthetic workstation X40
CO2 Absorber System
134°autoclavable CO2 absorber integrated bypass system, totally latex free.
Variable orifice flow sensor design.
35° (+-2) integrated heating system.
Bypass design with canister removes alarm.
No tools installation, easy maintenance.
![]()
System Specifications
| System Specifications | |
| Technical parameters | Specification |
| Machine | |
| Size | 1410 × 950 × 650 (H × W × D) |
| Weight | 110kg |
| Top cover | 30kg bearing weight |
| Size | 580 x 400mm |
| Display | |
| Type | Color TFT (touch screen) |
| Size | 8.4’ inches |
| Resolution | 640 × 480 pixels |
| Work surface light | LED |
| LED indication | |
| Alarm Indication | |
| AC power | |
| Battery | |
| Audio instruction | |
| Speaker | Alarm sounds |
| Control | |
| Button Press key | |
| Interface | |
|
RS232, VGA, USB Three auxiliary output power interface |
|
| Moving means | |
| Castor |
4 antistatic castors, diameter Φ125mm (2 brake Infront) |
| Toolbox | |
| Drawer | 200 × 392 × 398 mm(H×W×D)x2 |
| Respiratory System | |
| Air bellow | 1500mL |
| Absorption chamber | 1500mL |
| Connection |
Suction / ACGO ports: standard OD 22mm, ID 15mm, tapered connector; Exhalation ports: standard OD 22mm, ID 15mm, tapered connector. Manual breathing port: diameterΦ22cm |
| System leaks | < 40ml/min |
| System compliance | ≤ 4 mL / cmH2O |
| Resistance |
Inspiratory < 0.6 kPa; Expiratory < 0.6 kPa |
| Vaporizer | |
| Description | Parameter |
| Technical Specification | |
| Flowrate range | 0.2-15L/min |
| Connector type | Selectatec compatible, plug in, cage mount |
| Dosing methods | Pour-fil, Easy-fil, Quick-fil (Sevoflurane) |
| Working environment | |
| Working temperature | +15℃ ~ +35℃ |
| Relative humidity | 5%~95%(non-condensing) |
| Atmospheric pressure | 70kPa ~ 106kPa |
| Storage temperature | -20℃ ~ +55℃ |
| Concentration: |
0~5.0%: Isoflurane, Halothane 0 ~ 8.0%: Sevoflurane |
| Main technical parameters | |
| Description | Parameter |
| Display | 8” TFT, Touch screen, Top light |
| Ventilation Model | VCV, PCV, Manual, Standby SIMV-V (Optional:SIMV-P, SPONT/PSV) |
| Tidal volume | 20-1500ml(optional 10-1600ml), Electronic PEEP, Lung mechanics parameters. |
| Wave form | Paw-T, Flow-T, V-T, CO2-T |
| Loop | P-V, V-F |
|
Pressure Monitoring
|
Central: O2, N2O, Air Cylinder: O2, N2O |
|
Monitoring Parameter
|
Tidal volume, MV, Frequency, I : E, Airway Pressure, Pmin, Compliance, Resistance |
| Application | Adult and Infant |
| Vaporizer | Selected bar for two position |
| Gas supply | O2, N2O, Air |
|
6 tubes Flowmeter
|
O2: 0~10LPM; N2O: 0~12LPM; Air: 0~15LPM; |
| O2% | O2 sensor |
| Auxiliary O2 | Auxiliary O2 Flow meter(O2: 0~15LPM) (Optional) |
| ACGO | Yes |
| Battery |
NI-MH battery build-in. >90mins |
| Yoke | 2 ( O2, N2O) (Optional) |
| Gas Cylinder | O2, N2O (Optional) |
| Cycle Absorber | Intergrade, bypass Design, heating system. |
| Setting Parameter | |
| Description | Parameter |
| Tidal volume | 20~1500 mL(optional 10-1600ml) |
| Frequency | 1~100 bpm |
| Tinsp | 0.1~10.0s |
| I:E | 4:1~1:10 |
| Pause | 0~60% |
| PEEP | OFF, 3~30 cmH2O |
| Psupp | 0~70 cmH2O |
| Pressure Control | 5~70 cmH2O |
| Flow Trigger | 0.5~20 L/min |
| Pressure Trigger | 0~20 cmH2O |
| Ramp | 0~2s |
| Monitoring Parameter | |
| Description | Parameter |
| Tidal volume Inspiration | 0~2500 mL |
| Tidal volume Expiration | 0~2500 mL |
| MV | 0~60 L/min |
| MVspont | 0~60 L/min |
| Frequency | 0~100 bpm |
| Ratespont | 0~100 bpm |
| I : E | 9:1~1:99 |
| Ppeak | 0~100 cmH2O |
| Pmean | 0~100 cmH2O |
| PEEP | 0~100 cmH2O |
| Pplat | 0~100 cmH2O |
| O2% | 15~100% |
| Compliance | 0~300 mL/cmH2O |
| Resistance | 0~600 cmH2O/(L/s) |
| EtCO2 (Optional) | 0~13.3 % |
| FiCO2 (Optional) | 0~13.3 % |
| Alarm Parameter | |
| Description | Parameter |
| Tidal volume | |
| Upper limit | 30~2000 mL |
| Lower limit | OFF, 20~1500 mL |
| MV | |
| Upper limit | 1~99 L |
| Lower limit | 0~98 L |
| O2% (Optional) | |
| Upper limit | 22~100%, OFF |
| Lower limit | 20~99% |
| Airway Pressure | |
| Upper limit | 10~99 cmH2O |
| Lower limit | 1~98 cmH2O |
| Frequency | |
| Upper limit | 1~100 bpm |
| Lower limit | 0~99 bpm |
| EtCO2 (Optional) | |
| Upper limit | 0.1~13.3 % ; |
| Lower limit | 0~13.2 %; |
| FiCO2 (Optional) | |
| Upper limit | 0.1~13.3 % ; |
| Continue Pressure High | Airway pressure beyond(PEEP+15)cm H2O, continuedly(15+1)s |
| Apnea | 10~60 s, Increase: 1s |
| O2 supply down | < 0.28 MPa |
| Mains failure | Automatic switch battery |
| Battery low | < 10 min |
| Battery discharged | < 5 min |
| Mute | ≤120 s |
| Pressure low | < -10cmH2O |
| Power Specifications | |
| Description | Parameter |
| External AC power | |
| Input Voltage | 100 - 240V |
| Input Frequency | 50/60Hz |
| Input Power | <150 VA |
| Internal Battery | |
| Number of batteries | A battery pack |
| Battery Type | Nimh batteries |
| Rated battery voltage | 12VDC |
| Battery capacity | 4200mAh |
| Shutdown Delay | Less than 10min (using a new fully charged battery, low battery alert since the first post) |
| Shortest supply time | 90min |
| Charging time | 4h |
| Work environment | |
| Temperature | 10 ~ 40 ºC |
| Humidity | 5 ~ 95%, non-condensing |
| Environmental pressures | 70 ~ 106 kPa |
| Storage environment | |
| Temperature | -20 ~ 55 ºC |
| Humidity | 5~ 95%, non-condensing |
| Environmental pressures | 50 ~ 106 kPa |
![]()